{"id":60148,"date":"2026-01-29T15:39:29","date_gmt":"2026-01-29T13:39:29","guid":{"rendered":"https:\/\/medqmedicalsuppliers.co.za\/?post_type=product&#038;p=60148"},"modified":"2026-05-03T17:41:50","modified_gmt":"2026-05-03T15:41:50","slug":"aed-saver-1-pro","status":"publish","type":"product","link":"https:\/\/medqmedicalsuppliers.co.za\/?product=aed-saver-1-pro","title":{"rendered":"Aed Saver 1 Pro"},"content":{"rendered":"<h2>AED Saver 1 Pro<\/h2>\n<p>AED Saver 1 Pro is reliable for any BLS rescuer, can be easily switched in a Manual <a href=\"https:\/\/defibsplus.com.au\/the-maintenance-and-lifespan-of-aed-units\/#:~:text=How%20long%20your%20defibrillator%20lasts,lifetime%20of%202%2D5%20years.\">Defibrillator<\/a> giving to ALS responders the best decision-making control for a manual shock timing or an electric cardioversion (synchronized shock)<\/p>\n<p><a href=\"https:\/\/www.afrimedics.co.za\/product-category\/aed-defibrillators\/\"><strong>Defibrillator<\/strong><\/a><\/p>\n<p>Operation:\u00a0 \u00a0AED Semi-Automatic (default)ECG Monitoring Manual Asynchronous or Synchronous (used to convert atrial or ventricular tachyarrthythimias)<\/p>\n<p>Energies:\u00a0 \u00a0 \u00a0Standard max 200J or Power max 360J<\/p>\n<p>Waveform:\u00a0 \u00a0 Adaptive BTE (biphasic truncated exponential)conforming to patient chest\u2019s impedance<\/p>\n<p>Energy type:\u00a0 \u00a0Escalating from 50 to 360J<\/p>\n<p>AED Protocols:\u00a0 \u00a0Adult Standard escalating 150, 200, 200JAdult Power escalating 200, 250, 360JPediatric (Standard or Power) 50J fixed(AED adult shock protocols can be customized)<\/p>\n<p>Manual Protocol: Selected by users from 50 to 360J. For electric cardioversion (in Synchronous mode) the shock is synchronized to occur with the R wave of the ECG<\/p>\n<p>Energy Display: Screen provides the energy to deliver both in Manual mode or AED mode<\/p>\n<p>Charging time: \u22649 seconds with a new and fully charged battery depleted battery will result in a longer charging time<\/p>\n<p>Analysis time: IEC\/EN 60601-2-4 from 4 to 15 seconds<\/p>\n<p>Impedance: 20-200 ohms<\/p>\n<p>Sensitivity: IEC\/EN 60601-2-4 (AHADB, MITDB source), 97%<\/p>\n<p>Specificity: IEC\/EN 60601-2-4 (AHADB, MITDB source), 99%<\/p>\n<p>Controls: 2 buttons: ON\/OFF, shock button;3 buttons: to surf the menu;3 buttons: select energy, charge, disarm the device<\/p>\n<p>Indicators: Status LED indicator informing on device condition Battery gauge with remaining capacity rate Audible alerts and text display with service alarms<\/p>\n<p>Upgradeable: through a USB cable or memory card<\/p>\n<p>\u00a0<\/p>\n<p><strong>ECG Monitoring<\/strong><\/p>\n<p>Operations: Through defibrillation pads or standard ECG electrodes attached to a separate 2-Lead patient monitoring reusable cable SAV-C0017<\/p>\n<p>ECG size: Manual setting through the menu<\/p>\n<p>Heart Rate: 30-200 bpm<\/p>\n<p>Sweep Speed: 25 mm\/sec<\/p>\n<p>Standard: IEC\/EN 60601-2-27 less then the points 202.6.2.101;201.12.1.101.12,13; 208.6.6.2.101 not performed for the intended use of the device, as it is not intended for environments such as operating theatres or intensive care units<\/p>\n<p>Display: 5,7\u201d TFT colour, 640 x 480 pixel<\/p>\n","protected":false},"excerpt":{"rendered":"<h2>AED Saver 1 Pro<\/h2>\n<p>AED Saver 1 Pro is reliable for any BLS rescuer, can be easily switched in a Manual <a href=\"https:\/\/defibsplus.com.au\/the-maintenance-and-lifespan-of-aed-units\/#:~:text=How%20long%20your%20defibrillator%20lasts,lifetime%20of%202%2D5%20years.\">Defibrillator<\/a> giving to ALS responders the best decision-making control for a manual shock timing or an electric cardioversion (synchronized shock)<\/p>\n<p><a href=\"https:\/\/www.afrimedics.co.za\/product-category\/aed-defibrillators\/\"><strong>Defibrillator<\/strong><\/a><\/p>\n<p>Operation:\u00a0 \u00a0AED Semi-Automatic (default)ECG Monitoring Manual Asynchronous or Synchronous (used to convert atrial or ventricular tachyarrthythimias)<\/p>\n<p>Energies:\u00a0 \u00a0 \u00a0Standard max 200J or Power max 360J<\/p>\n<p>Waveform:\u00a0 \u00a0 Adaptive BTE (biphasic truncated exponential)conforming to patient chest\u2019s impedance<\/p>\n<p>Energy type:\u00a0 \u00a0Escalating from 50 to 360J<\/p>\n<p>AED Protocols:\u00a0 \u00a0Adult Standard escalating 150, 200, 200JAdult Power escalating 200, 250, 360JPediatric (Standard or Power) 50J fixed(AED adult shock protocols can be customized)<\/p>\n<p>Manual Protocol: Selected by users from 50 to 360J. For electric cardioversion (in Synchronous mode) the shock is synchronized to occur with the R wave of the ECG<\/p>\n<p>Energy Display: Screen provides the energy to deliver both in Manual mode or AED mode<\/p>\n<p>Charging time: \u22649 seconds with a new and fully charged battery depleted battery will result in a longer charging time<\/p>\n<p>Analysis time: IEC\/EN 60601-2-4 from 4 to 15 seconds<\/p>\n<p>Impedance: 20-200 ohms<\/p>\n<p>Sensitivity: IEC\/EN 60601-2-4 (AHADB, MITDB source), 97%<\/p>\n<p>Specificity: IEC\/EN 60601-2-4 (AHADB, MITDB source), 99%<\/p>\n<p>Controls: 2 buttons: ON\/OFF, shock button;3 buttons: to surf the menu;3 buttons: select energy, charge, disarm the device<\/p>\n<p>Indicators: Status LED indicator informing on device condition Battery gauge with remaining capacity rate Audible alerts and text display with service alarms<\/p>\n<p>Upgradeable: through a USB cable or memory card<\/p>\n<p>\u00a0<\/p>\n<p><strong>ECG Monitoring<\/strong><\/p>\n<p>Operations: Through defibrillation pads or standard ECG electrodes attached to a separate 2-Lead patient monitoring reusable cable SAV-C0017<\/p>\n<p>ECG size: Manual setting through the menu<\/p>\n<p>Heart Rate: 30-200 bpm<\/p>\n<p>Sweep Speed: 25 mm\/sec<\/p>\n<p>Standard: IEC\/EN 60601-2-27 less then the points 202.6.2.101;201.12.1.101.12,13; 208.6.6.2.101 not performed for the intended use of the device, as it is not intended for environments such as operating theatres or intensive care units<\/p>\n<p>Display: 5,7\u201d TFT colour, 640 x 480 pixel<\/p>\n","protected":false},"featured_media":93707,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[40103],"product_tag":[12250],"class_list":["post-60148","product","type-product","status-publish","has-post-thumbnail","product_cat-pads-and-accessories-for-saver-one-other-patient-care-incontinence-items","product_tag-aed-defibrillators","desktop-align-center","tablet-align-center","mobile-align-center","first","instock","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/medqmedicalsuppliers.co.za\/index.php?rest_route=\/wp\/v2\/product\/60148","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/medqmedicalsuppliers.co.za\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/medqmedicalsuppliers.co.za\/index.php?rest_route=\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/medqmedicalsuppliers.co.za\/index.php?rest_route=\/wp\/v2\/media\/93707"}],"wp:attachment":[{"href":"https:\/\/medqmedicalsuppliers.co.za\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=60148"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/medqmedicalsuppliers.co.za\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_brand&post=60148"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/medqmedicalsuppliers.co.za\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=60148"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/medqmedicalsuppliers.co.za\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=60148"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}